Skip to Content

A Comprehensive Guide to the MiPure Cell/Tissue miRNA Kit (Spin Column): Revolutionizing RNA and miRNA Extraction

The field of molecular biology has seen remarkable advancements in recent years, particularly in the study of microRNAs (miRNAs)—small, non-coding RNA molecules that play a critical role in gene regulation. For researchers seeking to unlock the potential of miRNAs in applications such as RT-PCR, chip analysis, Northern hybridization, and miRNA library preparation, the quality of RNA extraction is paramount. Enter the MiPure Cell/Tissue miRNA Kit (Spin Column), a cutting-edge solution designed to streamline RNA extraction and miRNA extraction from eukaryotic cells and animal tissues. This article explores the kit’s features, protocols, efficiency, and comparisons to other RNA isolation methods, offering a detailed resource for scientists and researchers.

 What is the MiPure Cell/Tissue miRNA Kit (Spin Column) ?

  • The MiPure Cell/Tissue miRNA Kit (Spin Column) is a specialized tool tailored for the extraction of small RNAs, particularly miRNAs (<200 nucleotides), from limited biological samples—fewer than 5 million eukaryotic cells or less than 100 mg of animal tissue. Leveraging spin column technology, this kit combines a high-performance RNA isolation reagent with silica gel column purification to deliver miRNAs of exceptional purity, free from large RNAs and genomic DNA contamination. Beyond miRNA extraction, the kit offers versatility by allowing the isolation of large RNAs (>200 nt) or total RNA (including miRNAs), depending on the researcher’s needs.
  • This kit is optimized for downstream applications such as RT-PCR, miRNA library preparation, Northern hybridization, and chip analysis, making it a go-to choice for studies requiring high-purity miRNA or RNA samples. With an extraction process completed in under an hour, it balances speed, efficiency, and reliability.

Learn more

Key Features of the MiPure Cell/Tissue miRNA Kit (Spin Column)

  1. High-Purity miRNA Extraction: The kit ensures that extracted miRNAs are free from contaminants like large RNAs and genomic DNA, critical for sensitive downstream applications.
  2. Spin Column Technology: Utilizes silica gel-based spin columns for efficient binding and purification of RNA, enhancing yield and consistency.
  3. Versatility: Allows extraction of miRNAs, large RNAs, or total RNA from the same sample, adaptable to various experimental designs.
  4. Small Sample Compatibility: Ideal for researchers working with limited starting material, such as fewer than 5 million cells or 100 mg of tissue.
  5. Rapid Protocol: The entire extraction process takes approximately one hour, saving valuable time in the lab.
  6. Broad Application Range: Purified RNA is suitable for RT-PCR, miRNA library preparation, Northern hybridization, and chip analysis.

How to Use the MiPure Cell/Tissue miRNA Kit (Spin Column) : Step-by-Step Protocol

The MiPure Cell/Tissue miRNA Kit (Spin Column) simplifies the RNA extraction process with a clear, efficient protocol. Below is a general outline of the steps involved :

  1. Sample Preparation: Begin with fewer than 5 × 10⁶ eukaryotic cells or less than 100 mg of animal tissue. Homogenize the sample thoroughly to ensure efficient lysis.
  2. Cell Lysis: Add the provided RNA Isolator reagent, a high-performance lysis solution, to disrupt cells or tissues and release RNA. This step also inactivates RNases to protect RNA integrity.
  3. Phase Separation (Optional): For total RNA extraction, perform a phase separation to isolate RNA from proteins and DNA. For miRNA-specific extraction, proceed directly to column purification.
  4. Binding to Spin Column: Apply the lysate to the silica gel spin column. Small RNAs (including miRNAs) bind selectively to the column matrix under optimized buffer conditions.
  5. Washing: Use wash buffers to remove impurities, ensuring high-purity miRNA or RNA elution.
  6. Elution: Elute the purified RNA or miRNA in a small volume of RNase-free water or buffer, ready for downstream applications.

The kit includes detailed instructions, with storage recommendations: Box 1 (containing light-sensitive components) should be stored at 2–8°C, while Box 2 is stable at 15–25°C for up to 18 months.

Why Choose the MiPure Cell/Tissue miRNA Kit (Spin Column)?

The MiPure Cell/Tissue miRNA Kit (Spin Column) stands out as a robust, efficient, and versatile solution for RNA extraction and miRNA extraction. Its spin column technology delivers high-purity miRNA from small samples in a fraction of the time required by traditional methods, making it an invaluable asset for labs focused on RT-PCR, miRNA library preparation, Northern hybridization, or chip analysis. When compared to other kits, its speed, specificity for small RNAs, and adaptability to various RNA fractions give it a competitive edge.

For researchers seeking reliable tools to advance their miRNA studies, the MiPure kit offers a blend of performance and practicality that’s hard to beat. Whether you’re extracting miRNA from eukaryotic cells or animal tissues, this kit promises to elevate your research with consistent, high-quality results.

Best Practices for miRNA Extraction with the MiPure Kit

To maximize the kit’s performance, consider these tips:

  • Sample Quality: Use fresh or properly preserved samples to avoid RNA degradation.
  • RNase-Free Conditions: Maintain an RNase-free environment to protect RNA integrity.
  • Sample Input: Adhere to recommended limits (5 × 10⁶ cells or 100 mg tissue) to avoid column clogging and ensure optimal yield.
  • Storage: Store eluted RNA at -80°C if not used immediately to preserve miRNA stability.

Applications of the MiPure Cell/Tissue miRNA Kit (Spin Column)

The kit’s versatility makes it a powerful tool across multiple research domains:

  1. RT-PCR: High-purity miRNA enables accurate quantification of miRNA expression levels using quantitative real-time PCR.
  2. miRNA Library Preparation: Extracted miRNAs are suitable for constructing small RNA libraries for next-generation sequencing.
  3. Northern Hybridization: The kit provides RNA samples optimized for detecting miRNA expression via blotting techniques.
  4. Chip Analysis: Purified miRNAs can be used in microarray studies to profile expression patterns.

Whether studying gene regulation, biomarker discovery, or disease mechanisms, the MiPure kit supports a wide range of experimental goals.

Comparing the MiPure Cell/Tissue miRNA Kit to Other RNA Extraction Kits

The market offers various RNA extraction kits, but not all are optimized for miRNA purification. Here’s how the MiPure Cell/Tissue miRNA Kit stacks up against competitors:

  • MiPure vs. TRIzol: TRIzol, a phenol-chloroform-based method, excels at total RNA extraction but often struggles to recover small RNAs like miRNAs efficiently. The MiPure kit outperforms TRIzol in miRNA extraction from small cell samples, thanks to its spin column purification.
  • MiPure vs. miRNeasy (QIAGEN): The miRNeasy kit also uses spin columns and is widely used for miRNA purification. While both kits are effective, MiPure’s protocol is faster (1 hour vs. slightly longer for miRNeasy) and tailored for smaller sample sizes, making it more cost-effective for specific studies.
  • MiPure vs. Norgen Total RNA Kit: Norgen’s kit focuses on total RNA without miRNA enrichment. The MiPure kit’s ability to separate miRNAs from large RNAs gives it an edge for researchers targeting miRNA purification from animal tissues.

User reviews of the MiPure Cell/Tissue miRNA Kit often highlight its ease of use, speed, and reliability for high-purity miRNA extraction, though some note that kits like miRNeasy may offer slightly higher yields with larger samples.